Building Systems Components

Insulated Wall and Roof Panels
Uninsulated Interior Walls and Floor
Window Systems

Precision Factory-Built Building Enclosure Systems

Panelized Enclosure Systems for the building professional

Design. Fabricate. Ship and Install.

Panelized Enclosures

Panelized Wall, Roof, and Floor Systems

We build insulated wall systems, insulated roof panels, and a variety of uninsulated panel systems. Many R-value options are available depending on the thermal efficiency requirement for your project. Tektoniks components can reach Passive House, Net-Zero, and USGBC LEED rated certifications. Panels are flat-packed and shrink wrapped in our factory before being shipped to the site on a flatbed truck. Oversize panels may require special shipping arrangements.

Wall Systems

OpenBuilt|Fiberboard|Passive House

An overview on our standard and custom wall systems.

R21 OpenBuilt Wall Panel
R21

OpenBuilt Wall

  • A. Interior Finish

    5/8" thickness

  • B. Service Layer

    2 1/2” thickness. Run mechanical systems and structural connections

  • C. Air|Vapor Control Layer

    7/16" OSB structural grid

  • D. Structural Framing & Insulation @ 24" O/C

    5 1/2" dense pack cellulose insulation

  • E. Weather Resistant Barrier

    5/8" ZIP Sheathing

  • F. Rainscreen

    1/4" drainage plane (optional)

  • G. Exterior Cladding

    Custom

R35 OpenBuilt Plus Wall Panel
R35/R45

OpenBuilt Plus Wall

  • A. Interior Finish

    5/8" thickness

  • B. Service Layer

    2 1/2” thickness. Run mechanical systems and structural connections

  • C. Air|Vapor Control Layer

    7/16" OSB structural grid

  • D. Structural Framing & Insulation @ 24" O/C

    9 1/2" dense pack cellulose insulation

  • E. Weather Resistant Barrier

    5/8" ZIP Sheathing

  • F. Rainscreen

    3/4" drainage plane

  • G. Exterior Cladding

    Custom

R26 Wood Fiberboard 6 Wall Panel
R26|R36

Wood Fiberboard 6 Wall

  • A. Interior Finish

    5/8" thickness

  • B. Service Layer

    2 1/2” thickness. Run mechanical systems and structural connections

  • C. Air|Vapor Control Layer

    7/16" OSB structural grid

  • D. Structural Framing & Insulation @ 24" O/C

    5 1/2" dense pack cellulose insulation

  • E. Weather Resistant Barrier

    R51 1 9/16" thick wood fiberboard

  • F. Rainscreen

    3/4" drainage plane

  • G. Exterior Cladding

    Custom

R32 Wood Fiberboard 8 Wall Panel
R32|R42

Wood Fiberboard 8 Wall

  • A. Interior Finish

    5/8" thickness

  • B. Service Layer

    2 1/2” thickness. Run mechanical systems and structural connections

  • C. Air|Vapor Control Layer

    7/16" OSB structural grid

  • D. Structural Framing & Insulation @ 24" O/C

    7  1/4" dense pack cellulose insulation

  • E. Weather Resistant Barrier

    R51 1 9/16" thick wood fiberboard

  • F. Rainscreen

    3/4" drainage plane

  • G. Exterior Cladding

    Custom

R53 Wood FIberboard PHlex Wall
R53

Wood Fiberboard PHlex Wall

  • A. Interior Finish

    5/8" thickness

  • B. Service Layer

    Up to 3 1/2” thickness. Run mechanical systems and structural connections

  • C. Air|Vapor Control Layer

    7/16" OSB structural grid

  • D. Structural Framing & Insulation @ 24" O/C

    Phlexible dimensions

  • E. Weather Resistant Barrier

    Phlexible dimensions

  • F. Rainscreen

    3/4" drainage plane

  • G. Exterior Cladding

    Custom

Ready to Start Building?

Submit Your Design

For architects, developers, and contractors

Wall

Panel Dimensions

Maximum wall panel dimensions are typically 9 feet 6 inches tall by up to 32 feet long. Wall panels can be built up to 10 feet 6 inches tall.

Wall panels are typically oriented horizontally and stacked vertically.
Roof and Floor Systems

Vented|Unvented|Floor System

R44 Nepor SIP Roof
R44

NEOPOR® SIP Vented Roof

  • A. Interior Finish

    3/4" wood ceiling boards or other finish

  • B. Air|Vapor Control Layer

    7/16" OSB structural grid

  • C. Insulation

    NEOPOR® EPS continuous insulation

  • D. Ventilation

    2X strapping 24" O/C

  • E. Roof Deck

    5/8" ZIP Sheathing

R44 Unvented Roof
R44

Unvented Roof

  • A. Interior Finish

    3/4" wood ceiling boards or other finish

  • B. Air|Vapor Control Layer

    7/16" OSB structural grid

  • C. Rafter

    11 7/8" wood I-joist

  • C. Insulation

    Dense pack cellulose insulation

  • E. Roof Deck

    5/8" ZIP Sheathing

R49 Vented Roof
R49

Vented Roof

  • A. Interior Finish

    3/4" wood ceiling boards or other finish

  • B. Air|Vapor Control Layer

    7/16" OSB structural grid

  • C. Rafter

    14" wood I-joist

  • D. Insulation

    Dense pack cellulose insulation

  • E. Ventilation

    Top flange for air flow, cellulose held back with barrier

  • F. Roof Deck

    5/8" ZIP Sheathing

R51 Unvented Roof
R51

Unvented Roof

  • A. Interior Finish

    3/4" wood ceiling boards or other finish

  • B. Air|Vapor Control Layer

    7/16" OSB structural grid

  • C. Rafter

    14" wood I-joist

  • D. Insulation

    Dense pack cellulose insulation

  • E. Roof Deck

    5/8" ZIP Sheathing

Roof and Floor

Panel Dimensions

The maximum dimensions for roof and floor panels are 8’ wide by the length of the rafter/joist. Roof panel overhangs are typically 2’ at eaves and 1’ at rakes.

Longer and shorter overhangs are available.
Window Systems

Marvin Integrity|Unilux|Wasco

Learn more about our window options on all wall systems

Protecting the investment of the professional.

Qualtiy Control and Assurance

TEKTONIKS standardizes quality. Third party verification, by TR Arnold, provides state agencies and consumers confirmation that engineering, code compliance, and off-site construction adheres to specifications.

Next Steps

Related information for document standards, shipping to site information, and cost details.

For architects, developers, and builders wanting to learn more about our document standards, additional services for engineering and site delivery, and cost estimations. 

Our Specifications

01

Document Standards

Submitting your designs to Tektoniks document standards

Drawings and Plans

Clients submit engineered and fully developed drawing plan set with Revit models if possible. Engineered stamped drawings need to use Tektoniks connection details.

Additional Services

We offer additional assistance, reviews, and design|engineering services through Bensonwood for an added cost.

02

Shipping and Site Assembly

Shipping from our production facilities to client site

Shipping and Freight

All shipping costs for building systems components are freight on board at Tektoniks manufacturing facilities in Keene and Walpole, New Hampshire. All outbound finished timber products ship sealed in a protective wrap for transport. Tektoniks unloads all inbound freight and loads outbound freight. Client absorbs storage fees for any components left in our staging area longer than agreed upon in the contract.

Construction Site Requirements

  • Equipment to unload and erect components
  • Site storage
  • An adequate area to unload
  • Site labor crew with knowledge of off-site fabricated component installation

Additional Services

Tektoniks offers on-site assistance for added costs.

03

Cost Details

Estimating, component cost, and payment structure

Estimating

Tektoniks quotes a maximum of two versions for each project. Fees apply for additional quotes of the same project.

Building Component Cost and Project Templates

  • Square foot rough order of magnitude pricing
  • Project type scale
  • Site costs

Payment Structure

  • Deposit
  • Production commences payment 40%
  • Production complete payment 50%

State Panelization Laws

Clients sole responsibility to ensure they meet all state and federal laws in the build area.

Unparalleled Services

Offering a range of building products throughout North America using 45 years of proven design|build experience through Bensonwood and Unity Homes.

Have questions about TEKTONIKS?

Contact Us

Talk with our team of professionals today

Bensonwood Logo

Passive House | Timberframe | Custom Homes

Unity Logo

Sustainable. Comfortable. Healthy Homes.